Geographic redundancy across healthcare locations is built by physically distributing critical network connections, systems, and data storage across multiple sites, ensuring that a failure at one location never threatens the continuity of patient care. For healthcare organisations, this is not a luxury but a necessity: patient care, medical systems, and electronic records require uninterrupted availability. The questions below guide you step by step through building a robust, compliant, and future-proof redundant network infrastructure for healthcare locations.
Which components make a healthcare network geographically redundant?
A geographically redundant healthcare network consists of four core elements: diversified physical connections between locations, redundant network equipment at each site, distributed data storage, and automatic failover mechanisms. All these components must work together so that no single failure leads to complete outage.
In practice, this means each location needs at least two independent connections to the rest of the network, preferably via different physical routes and providers. Fibre-optic connections form the backbone here, thanks to their high bandwidth, low latency, and reliability. Beyond the connections themselves, network equipment such as routers, switches, and firewalls must also be deployed redundantly, including power supplies.
Distributing applications and data across multiple locations is equally essential. Think of distributed servers, mirrored databases, and cloud connections that keep patient data and medical applications accessible even when one location fails. Critical systems such as electronic patient records (EPD/ECD), medication management, alarm systems, and emergency communications must remain available at all times — an outage lasting even a few minutes can have direct consequences for patient safety. Network solutions for healthcare environments combine all these layers into a single coherent whole that safeguards both availability and security.
What is the difference between geographic redundancy and high availability?
High availability focuses on preventing outages within a single location through duplicate components and automatic switching, while geographic redundancy protects against the complete failure of a location by physically distributing systems and connections across multiple geographically separated sites. Both concepts complement each other and are both necessary in healthcare environments.
A high-availability system has, for example, two power supplies, two network cards, and a redundant storage controller. If one component fails, the other takes over seamlessly. This works well for hardware failures, but offers no protection if a fire, power outage, or cyberattack affects an entire building or data centre.
Geographic redundancy goes a step further. The same applications run and data are stored at two or more physically separated locations. If one location fails completely, services continue automatically via the other. In healthcare, where systems such as radiology, medication management, and emergency communications must be available around the clock, the combination of both approaches is the only responsible choice.
Which connection technologies are suitable for healthcare locations?
For geographic redundancy between healthcare locations, fibre-optic connections are the most suitable primary technology, supplemented by SD-WAN for intelligent routing and management. As a secondary connection, an alternative connection technology via a different physical route provides the diversity needed to guarantee genuine redundancy. A critical consideration here is physical route dependency: two connections that share the same duct or street cabinet offer no real redundancy, even if they come from different providers.
Fibre optic as the primary connection
Fibre optic offers the highest bandwidth, lowest latency, and maximum reliability for medical data streams such as imaging, video consultations, and real-time patient monitoring. Dedicated fibre connections between locations — also known as point-to-point or dark fibre — give you full control over capacity and security. As healthcare organisations connect more locations, devices, and cloud environments, the demand for capacity continues to grow. Adtran’s FSP 3000 platform supports optical transport and capacity expansion over fibre, including Data Centre Interconnect, making it well suited to scaling healthcare networks without disrupting existing infrastructure. With optical network solutions, these connections can also be equipped with encryption at layer 1 or 2 using Adtran ConnectGuard, which provides significant added value in healthcare settings where sensitive patient data is in transit.
SD-WAN for intelligent management
SD-WAN makes it possible to centrally manage and intelligently utilise multiple connections — both fibre and alternative connections. The system continuously monitors the quality of each connection and automatically reroutes traffic in the event of degradation or failure. For healthcare locations, this is valuable because it allows you to prioritise critical traffic such as emergency communications and medical images, regardless of which connection is active at any given moment. Adtran’s FSP 150 platform supports Carrier Ethernet access and performance monitoring at the network edge, providing clear demarcation and insight into connection quality across multiple sites.
Network segmentation for medical devices and IoT
A geographically redundant healthcare network must also account for the growing number of connected medical devices, IoT sensors, staff devices, and guest systems. Mixing these on a single network segment creates both security risks and performance issues. Proper segmentation — separating medical equipment, building systems, staff workstations, and guest access into distinct network zones — limits the impact of a failure or security incident to a single segment and prevents it from spreading across the entire network. This segmentation must be maintained consistently across all locations and failover scenarios.
How do you determine the right RPO and RTO for healthcare applications?
The Recovery Point Objective (RPO) indicates how much data loss is acceptable in the event of a failure; the Recovery Time Objective (RTO) determines how quickly systems must be operational again. For healthcare applications, these values are established based on the clinical impact of an outage: the more critical the application to direct patient care, the lower the RPO and RTO must be.
Emergency department systems, medication distribution, and intensive care monitoring typically require an RTO of minutes or even seconds, and an RPO that is virtually zero. Administrative systems such as billing or scheduling can tolerate higher values. Carry out a risk analysis for each application, weighing clinical impact, legal obligations, and recovery costs.
In practice, RPO and RTO also determine the technical architecture. An RPO of zero requires synchronous data mirroring between locations, which presupposes a low-latency connection. An RTO of minutes demands automatic failover without manual intervention. Always align technical choices with the established values, not the other way around.
How does automatic failover between healthcare locations work?
Automatic failover between healthcare locations works by continuously monitoring the availability and quality of connections and systems, and automatically switching traffic or workloads to a functioning location or connection when a failure is detected — without requiring human intervention.
The process begins with monitoring. Network equipment and management systems continuously check the status of connections, servers, and applications using protocols such as BFD (Bidirectional Forwarding Detection) or OSPF. When the system detects a failure, it activates an alternative route or a standby system at another location within seconds.
Effective failover in healthcare environments also requires that sessions and application states are preserved. A user working on a radiology workstation in the middle of reviewing an image must not be forced to log in again or lose data. This places demands on the application layer, not just the network. Real-time fibre monitoring supports this: by detecting anomalies in physical fibre connections before they cause actual outages, you can switch proactively rather than recover reactively. Adtran ALM and Mosaic Fiber Director provide this kind of physical-layer visibility, helping operations teams identify and localise faults quickly. Clear agreements on responsibilities between internal teams and external suppliers — including defined escalation paths and response times — are equally important to ensure that the right people can act without delay during an incident.
Test failover procedures regularly in a controlled environment. A redundant network that has never been tested offers no guarantees when a real incident occurs.
What compliance requirements must a redundant healthcare network meet?
A redundant healthcare network in the Netherlands and the EU must comply with the GDPR for the protection of patient data, the NEN 7510 standard for information security in healthcare, and the NIS2 directive for network and information security of essential services. Depending on the organisation, sector-specific requirements from the IGJ or health insurers may also apply.
The GDPR requires healthcare organisations to implement appropriate technical and organisational measures to protect personal data. For a redundant network, this means data encryption is mandatory — both in transit and at rest — and that access to patient data must be strictly controlled and logged. Protection of sensitive data at the network level is an essential building block for this. Adtran ConnectGuard provides hardware-based encryption at layer 1 and layer 2, making it possible to demonstrate compliance with the technical security requirements of the GDPR and NEN 7510 at the connection level. Netways Europe advises on the appropriate encryption approach based on the specific connection type and data sensitivity.
NEN 7510 goes beyond technical measures and also covers policy, procedures, and awareness. The standard requires a risk analysis as the basis for security measures, which aligns well with determining RPO and RTO. NIS2 adds incident reporting obligations and sets requirements for the continuity plans of organisations classified as essential or important — a category that includes many healthcare institutions.
Also ensure that your suppliers and partners meet the same standards. A redundant infrastructure is only as strong as the weakest link in the chain, including the parties that manage or support your network. Network-level encryption solutions help you demonstrably meet the technical security requirements set by all these frameworks.
Modernising existing infrastructure without disrupting care
Many healthcare organisations are working with network infrastructure that was not originally designed for the current scale of connected systems, locations, and devices. Upgrading this infrastructure while keeping critical care processes running is one of the most practical challenges in building geographic redundancy.
A phased approach — starting with the most critical connections and highest-risk single points of failure — allows organisations to improve resilience incrementally without large-scale disruption. Migrating an EPD to a cloud environment, for example, creates an opportunity to simultaneously upgrade the underlying WAN connections and introduce proper redundancy and encryption. The CIO may prioritise simplified management and scalability, while the CISO focuses on secure data transport and access control. A well-designed network architecture addresses both: redundant, encrypted fibre connections between locations and cloud environments, combined with centralised visibility through tools such as Adtran’s Mosaic Network Controller, bring these interests together in a single manageable solution. Netways Europe supports this process from initial analysis through to implementation and ongoing management.
Want to know how to make your healthcare network geographically redundant in a way that fits your specific situation? We are happy to think along with you, from initial analysis to full implementation.
Klaar voor de volgende stap?
Bekijk onze oplossingen of neem direct contact op met een van onze experts.