In a healthcare organisation, you should test failover at least twice a year, preferably every quarter. The more critical the systems you monitor, the higher the testing frequency. Hospitals and other healthcare institutions with business-critical networks that support patient safety cannot afford to wait for an outage to demonstrate that the system is not working as expected.
The healthcare sector differs from other sectors in that a network outage can have direct consequences for patient care. Think of medical equipment transmitting data, electronic health records that must be available 24/7, or alarm systems that depend on a stable connection. Network redundancy in a hospital is not a luxury: it is a basic requirement. In this article, we answer the most frequently asked questions about failover testing in a healthcare environment.
What are the risks of an untested failover system in healthcare?
An untested failover system provides a false sense of security. You have installed the technology, but you do not know whether it actually functions at the moment you need it. In healthcare, this means that systems can fail at the moment patient safety depends on them, without a working fallback option in place.
The risks are concrete and serious. Electronic health records becoming inaccessible, medical monitoring equipment losing its connection, or a communication system going down during an emergency. In all these situations, the expectation is that the network automatically switches to a redundant connection. If that switchover has never been tested, a configuration error, an outdated IP address, or an unsynchronised routing table can cause the failover to simply not occur.
A further complication specific to healthcare is physical route dependency. Primary and backup connections that share the same physical fibre path offer no real redundancy: a single cable break can take both links down simultaneously. Verifying that backup connections follow genuinely separate physical routes is therefore an essential part of any failover test, not an optional extra.
Added to this, supervisory bodies and standards such as NEN 7510 and NIS2 require healthcare institutions to demonstrably guarantee the availability of their information systems. An untested failover system is therefore not only an operational risk, but also a compliance risk.
How often should you test failover in a healthcare environment?
For most healthcare organisations, a minimum frequency of twice a year applies for full failover tests, supplemented by quarterly checks of the technical configuration. Systems that directly support patient care deserve a higher testing frequency: a full test every quarter is the norm in that case. The appropriate frequency depends on the risk class of the systems and the requirements of laws and regulations.
A good rule of thumb is to always perform your failover test before planned changes to the infrastructure, and again immediately afterwards. Firmware updates, new equipment, or changes to the network topology can unintentionally affect the failover configuration. By systematically testing around these moments, you prevent a change elsewhere from unexpectedly creating a weak point.
In addition to periodic tests, it is wise to conduct an evaluation after every significant outage: did the failover work as expected? If not, that is a direct reason for an additional test cycle. Business continuity in a healthcare network is not a static given: it requires ongoing attention. Tools such as Adtran ALM and Mosaic Fiber Director can support continuous monitoring of physical fibre connections, making it possible to detect anomalies between scheduled tests rather than discovering them only when an outage has already occurred.
Which systems in a healthcare organisation have priority in failover tests?
The systems with the highest priority in failover tests are those that directly support patient care or patient safety. These include electronic health records (EHR), medication data systems, medical monitoring equipment, alarm systems, imaging systems such as PACS, and communication platforms for healthcare staff. These systems must never be inaccessible under any circumstances.
A practical approach is to draw up a priority matrix based on two criteria: the impact of an outage on patient care, and the recovery time that is acceptable. Systems in the highest category are tested most frequently and most thoroughly. Systems that are less time-critical, such as administrative applications or internal communication tools, can be tested at a lower frequency.
Network segmentation is a related consideration that is often overlooked during failover planning. Medical devices, IoT equipment, staff workstations, and guest devices typically operate on separate network segments. A failover test should verify that each segment switches correctly and that segmentation policies remain intact after the switchover — a misconfigured VLAN following a failover event can expose clinical systems to unintended traffic.
Do not forget the network infrastructure itself either. Switches, routers, and the optical connections that form the foundation of your healthcare network are just as critical as the applications running on them. A failover test that only checks the application layer but skips the underlying network infrastructure is incomplete. Where optical transport capacity is a limiting factor — for instance when growing numbers of connected care devices or additional locations increase bandwidth demand — solutions such as the Adtran FSP 3000 can extend fibre capacity without requiring a full infrastructure replacement.
What is the difference between a tabletop exercise and a live failover test?
A tabletop exercise is a theoretical walkthrough of a failover scenario in which those involved discuss together what should happen in the event of an outage. A live failover test is an actual test in which you shut down the primary connection or primary system to verify that the failover occurs automatically and correctly. Both methods are valuable, but they measure different things.
What does a tabletop exercise deliver?
A tabletop exercise helps you to assess procedures, responsibilities, and communication lines. You discover whether everyone knows their role in an emergency, whether the documentation is correct, and whether there are blind spots in the recovery plan. It is a low-threshold way to validate your Business Continuity Plan without the risk of disrupting care delivery. It is also the right moment to clarify responsibilities between internal IT teams and external suppliers — particularly relevant when multiple vendors are involved in managing different parts of the network.
What does a live failover test deliver?
A live failover test demonstrates whether the technology actually works. You test whether the automatic switchover occurs, how long it takes, and whether all systems function correctly after the failover. This is the only way to discover technical errors in the configuration. A live test carries more risk and requires careful preparation, including a fallback plan in case the test unexpectedly causes problems.
In practice, you combine both: use tabletop exercises for training people and processes, and live tests for validating the technology. For healthcare organisations, it is wise to schedule live tests outside peak hours and always have a technical team on standby. Ensure that network equipment involved in the failover path — including demarcation points and access devices — is reachable for diagnosis and recovery during the test, so that any unexpected behaviour can be resolved quickly without affecting care delivery.
How do you document a failover test to comply with NEN 7510 and NIS2?
A well-documented failover test contains at minimum: the date and time of the test, the systems and connections that were tested, the test method, the outcome, any deviations from the expected outcome, and the follow-up actions. NEN 7510 and NIS2 both require demonstrable control measures for availability and business continuity, and test reports are the evidence for this.
Ensure that the documentation aligns with your broader Information Security Management System (ISMS). Test results must be traceable, managed with version control, and available for internal audits or external supervisors. A separate spreadsheet per test is a start, but a structured system that maintains test history gives a much stronger picture of your maturity in the area of business continuity.
Also record the lessons learned. A test that reveals something is more valuable than a test that reveals nothing, but only if you convert the findings into concrete improvements. Therefore, document not only what went well, but also what can be improved and what action has been taken for that. This makes your file credible and demonstrably robust. For organisations working with sensitive patient data, protection of sensitive data is an integral part of this process — including verifying that encrypted connections between care locations, data centres, and cloud environments remain active and correctly configured after a failover event.
When is an external party needed for failover tests in healthcare?
An external party is needed when the internal knowledge or capacity is lacking to carry out a full failover test objectively and safely. This is the case with complex network topologies, when testing critical systems where errors directly impact patient care, or when an independent assessment is required for compliance purposes. An external party also brings a fresh perspective that can identify internal blind spots.
Healthcare organisations with a limited IT team run the risk of failover tests being continually postponed because day-to-day operations take priority. An external partner provides structure and continuity in the testing programme, without fully burdening your internal team. Moreover, a specialised party has experience with comparable environments, which benefits the quality of the test and the interpretation of the results.
External guidance is also advisable for major infrastructure changes, such as a migration to a new network architecture, the modernisation of existing fibre connections, or the introduction of new redundant connections. Modernising fibre infrastructure in a live healthcare environment requires careful planning to avoid disrupting care processes — an area where experience with phased migration and parallel operation is essential. Real-time fibre optic monitoring and proactive network management are examples of services that contribute to a demonstrably reliable infrastructure, so that your failover tests are not just a snapshot but part of a continuous monitoring process.
Would you like to know how your healthcare organisation can get network redundancy and failover testing procedures in order? We are happy to think along with you, from advice to implementation and management.
Ready for the next step?